1.Standar: IEC61008-1
2. Tipe éléktromagnétik
3. Nyegah kacilakaan bocor di sumberna
4. Tepat dina struktur, kirang unsur, tanpa daya bantu
5. Skenario: perusahaan industri sareng pertambangan, gedong perdagangan, perdagangan sareng kulawarga
| Standar | IEC/EN 61008 | |
| Fitur listrik | Modeu | Tipe éléktromagnétik, tipe éléktronik |
| Tipe (bentuk gelombang tina bocorna bumi anu karasa) | A,AC | |
| Arus anu dipeunteun Dina | 16,25,32,40,63,80,100,125A | |
| Urang Polandia | 2P, 4P | |
| Tegangan anu dipeunteun Ue | AC 230/400V | |
| Sensitivitas anu dipeunteun I△n | 0.01,0.03,0.1,0.3,0.5A | |
| Tegangan insulasi Ui | 500V | |
| Kapasitas nyieun jeung megatkeun sésa anu dipeunteun I△m | 1250A | |
| Arus hubung singkat I△c | 10000A | |
| Frékuénsi anu dipeunteun | 50/60Hz | |
| Sekring SCPD | 10000A | |
| Tingkat polusi | 2 |
| Standar | IEC/EN 61009 | ||
| Fitur mékanis | Kahirupan listrik | 4100 | |
| Kahirupan mékanis | 10000 | ||
| Darajat panyalindungan | IP20 | ||
| Suhu lingkungan (kalayan rata-rata poean ≤35°C) | °C | -25~+40 | |
| Suhu panyimpenan | °C | -25~+70 | |
| Pamasangan | Jenis sambungan terminal | Kabel/busbar tipe-U/busbar tipe-Pin | |
| Ukuran luhur terminal pikeun kabel | mm² | 35 | |
| AWG | 18-3 | ||
| Ukuran luhur terminal pikeun busbar | mm² | 35 | |
| AWG | 18-3 | ||
| Torsi pangencangan | N*m | 2.5 | |
| Dina-Ibs | 22 | ||
| Pemasangan | Dina rel DIN EN 60715 (35mm) nganggo alat klip gancang | ||
| Sambungan | Ti luhur jeung handap |