RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal

The converter frékuénsi utamana diwangun ku panyaarah (AC ka DC), filter, inverter (DC ka AC), Unit ngerem, Unit nyetir, Unit deteksi, Unit processing mikro, jsb inverter The ngaluyukeun tegangan jeung frékuénsi catu daya kaluaran. ku megatkeun IGBT internal, sarta nyadiakeun tegangan catu daya diperlukeun nurutkeun pangabutuh sabenerna motor pikeun ngahontal tujuan hemat energi jeung pangaturan speed.Sajaba ti éta, inverter ngabogaan loba fungsi panyalindungan, kayaning overcurrent, overvoltage, panyalindungan overload, jsb.


  • RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal
  • RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal
  • RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal
  • RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal
  • RDI67 runtuyan VFD (Variabel-frékuénsi Girang) - Fan / Pompa cai Control Universal

Rincian produk

Aplikasi

Parameter

Sampel & Struktur

Diménsi

Bubuka produk

The converter frékuénsi utamana diwangun ku panyaarah (AC ka DC), filter, inverter (DC ka AC), Unit ngerem, Unit nyetir, Unit deteksi, Unit processing mikro, jsb inverter The ngaluyukeun tegangan jeung frékuénsi catu daya kaluaran. ku megatkeun IGBT internal, sarta nyadiakeun tegangan catu daya diperlukeun nurutkeun pangabutuh sabenerna motor pikeun ngahontal tujuan hemat energi jeung pangaturan speed.Sajaba ti éta, inverter ngabogaan loba fungsi panyalindungan, kayaning overcurrent, overvoltage, panyalindungan overload, jsb.

Fitur

1. Frékuénsi konversi hemat energi

2. Power faktor santunan hemat energi - alatan peran kapasitor filter internal of inverter nu, leungitna kakuatan réaktif diréduksi jeung kakuatan aktif tina grid nu ngaronjat.

3. Lemes mimiti hemat energi - ngagunakeun fungsi mimiti lemes tina converter frékuénsi bakal nyieun dimimitian ayeuna dimimitian ti enol, sarta nilai maksimum moal ngaleuwihan arus dipeunteun, ngurangan dampak dina grid kakuatan sarta sarat pikeun kapasitas catu daya. , sareng manjangkeun umur jasa alat sareng klep.Biaya pangropéa pakakas disimpen.

Modél No.

5

Kaayaan kerja normal sareng kaayaan instalasi

2.1 Kalembaban: Kalembaban relatif teu kedah ngaleuwihan 50% dina suhu Max 40 ° C, sareng kalembaban anu langkung luhur tiasa ditampi dina suhu anu langkung handap.Kondensasi kudu dijaga anu disababkeun ku parobahan suhu.
Nalika suhu luhur + 40 ° C, loaction kudu well-ventilated.Nalika lingkungan teu baku, punten nganggo telekontrol atanapi kabinet listrik.Kahirupan kerja inverter kapangaruhan ku lokasi pamasangan.Longtime kontinyu ngagunakeun, hirup kapasitor electrolytic di inverter moal ngaleuwihan 5 taun, cooling hirup kipas moal ngaleuwihan 3 taun, bursa jeung perawatan kudu dipigawé saméméhna.

1.Frequency konversi énergi hemat

Énergi hemat converter frékuénsi utamana ditémbongkeun dina aplikasi tina kipas na pompa cai.Saatos régulasi laju frékuénsi variabel diadopsi pikeun beban kipas sareng pompa, tingkat hemat daya nyaéta 20% ~ 60%, sabab konsumsi kakuatan saleresna kipas sareng beban pompa dasarna sabanding sareng kakuatan katilu laju.Nalika aliran rata-rata anu dibutuhkeun ku pangguna leutik, kipas sareng pompa ngadopsi régulasi laju konversi frékuénsi pikeun ngirangan kagancanganna, sareng éfék hemat energi écés pisan.Nalika kipas sareng pompa tradisional nganggo baffle sareng klep pikeun pangaturan aliran, laju motor dasarna henteu robih, sareng pamakean kakuatan sakedik robih.Numutkeun statistik, konsumsi kakuatan kipas sareng motor pompa nyababkeun 31% tina konsumsi kakuatan nasional sareng 50% tina konsumsi kakuatan industri.Penting pisan ngagunakeun alat pangaturan laju konversi frékuénsi dina beban sapertos kitu.Ayeuna, aplikasi anu langkung suksés kalebet suplai cai tekanan konstan, pangaturan laju frékuénsi variabel tina sababaraha kipas, AC sentral sareng pompa hidrolik.

2.Frequency konversi énergi hemat

Énergi hemat converter frékuénsi utamana ditémbongkeun dina aplikasi tina kipas na pompa cai.Saatos régulasi laju frékuénsi variabel diadopsi pikeun beban kipas sareng pompa, tingkat hemat daya nyaéta 20% ~ 60%, sabab konsumsi kakuatan saleresna kipas sareng beban pompa dasarna sabanding sareng kakuatan katilu laju.Nalika aliran rata-rata anu dibutuhkeun ku pangguna leutik, kipas sareng pompa ngadopsi régulasi laju konversi frékuénsi pikeun ngirangan kagancanganna, sareng éfék hemat energi écés pisan.Nalika kipas sareng pompa tradisional nganggo baffle sareng klep pikeun pangaturan aliran, laju motor dasarna henteu robih, sareng pamakean kakuatan sakedik robih.Numutkeun statistik, konsumsi kakuatan kipas sareng motor pompa nyababkeun 31% tina konsumsi kakuatan nasional sareng 50% tina konsumsi kakuatan industri.Penting pisan ngagunakeun alat pangaturan laju konversi frékuénsi dina beban sapertos kitu.Ayeuna, aplikasi anu langkung suksés kalebet suplai cai tekanan konstan, pangaturan laju frékuénsi variabel tina sababaraha kipas, AC sentral sareng pompa hidrolik.

3.Application dina ngaronjatkeun tingkat prosés jeung kualitas produk

Konverter frékuénsi ogé tiasa seueur dianggo dina sababaraha widang kontrol alat mékanis sapertos pangiriman, angkat, ékstrusi sareng alat mesin.Éta tiasa ningkatkeun tingkat prosés sareng kualitas produk, ngirangan dampak sareng bising alat, sareng manjangkeun umur jasa alat.Saatos nganut kontrol régulasi laju konversi frékuénsi, sistem mékanis disederhanakeun, sareng operasi sareng kontrol langkung merenah.Sababaraha malah bisa ngarobah spésifikasi prosés aslina, sahingga ngaronjatkeun fungsi sakabéh parabot.Salaku conto, pikeun tékstil sareng mesin ukuran anu dianggo dina seueur industri, suhu di jero mesin disaluyukeun ku cara ngarobah jumlah hawa panas.Kipas sirkulasi biasana dianggo pikeun ngirimkeun hawa panas.Kusabab laju kipas angger, jumlah hawa panas anu disuap ngan ukur tiasa disaluyukeun ku damper.Lamun damper nu gagal pikeun nyaluyukeun atawa improperly disaluyukeun, mesin molding bakal leungit kontrol, sahingga mangaruhan kualitas produk rengse.Kipas sirkulasi dimimitian dina laju anu luhur, sareng ngagem antara sabuk drive sareng bantalan parah pisan, ngajantenkeun sabuk drive janten konsumsi.Saatos pangaturan laju konversi frékuénsi diadopsi, pangaturan suhu tiasa diwujudkeun ku konverter frékuénsi pikeun otomatis nyaluyukeun laju kipas, anu ngarengsekeun masalah kualitas produk.Sajaba ti éta, konverter frékuénsi bisa kalayan gampang ngamimitian kipas dina frékuénsi lemah sareng speed low, ngurangan maké antara sabuk drive na bearing nu, manjangkeun umur jasa pakakas, sarta ngahemat énergi ku 40%.

4.Realization motor mimiti lemes

Mimitian teuas motor teu ngan bakal ngabalukarkeun dampak serius dina grid kakuatan, tapi ogé merlukeun teuing kapasitas grid kakuatan.Arus ageung sareng geter anu dibangkitkeun nalika ngamimitian bakal nyababkeun karusakan anu ageung kana baffles sareng klep, sareng bakal ngabahayakeun pisan pikeun kahirupan jasa alat sareng pipa.Sanggeus ngagunakeun inverter nu, fungsi mimiti lemes tina inverter bakal nyieun robah ayeuna dimimitian ti enol, sarta nilai maksimum moal ngaleuwihan arus dipeunteun, ngurangan dampak dina grid kakuatan sarta sarat pikeun kapasitas catu daya, dilegaan jasa. hirup pakakas sarta valves, sarta ogé nyimpen biaya pangropéa pakakas

Spésifikasi

Jinis tegangan: 380V sareng 220V
Kapasitas Motor Applicative: 0.75kW mun 315kW
Spésifikasi tingali Table1

Voltaseu Modél No. Kapasitas dipeunteun (kVA) Arus kaluaran dipeunteun (A) Motor aplikatif (kW)
380V
tilu-fase
RDI67-0.75G-A3 1.5 2.3 0.75
RDI67-1.5G-A3 3.7 3.7 1.5
RDI67-2.2G-A3 4.7 5.0 2.2
RDI67-4G-A3 6.1 8.5 4.0
RDI67-5.5G / 7.5P-A3 11 13 5.5
RDI67-7.5G / 11P-A3 14 17 7.5
RDI67-11G / 15P-A3 21 25 11
RDI67-15G / 18.5P-A3 26 33 15
RDI67-18.5G / 22P-A3 31 39 18.5
RDI67-22G / 30P-A3 37 45 22
RDI67-30G / 37P-A3 50 60 30
RDI67-37G / 45P-A3 61 75 37
RDI67-45G / 55P-A3 73 90 45
RDI67-55G / 75P-A3 98 110 55
RDI67-75G / 90P-A3 130 150 75
RDI67-93G / 110P-A3 170 176 90
RDI67-110G / 132P-A3 138 210 110
RDI67-132G / 160P-A3 167 250 132
RDI67-160G / 185P-A3 230 310 160
RDI67-200G / 220P-A3 250 380 200
RDI67-220G-A3 258 415 220
RDI67-250G-A3 340 475 245
RDI67-280G-A3 450 510 280
RDI67-315G-A3 460 605 315
220V
fase tunggal
RDI67-0.75G-A3 1.4 4.0 0.75
RDI67-1.5G-A3 2.6 7.0 1.2
RDI67-2.2G-A3 3.8 10.0 2.2

runtuyan 220V fase tunggal

Motor aplikatif (kW) Modél No. Diagram Ukuran: (mm)
220 séri A B C G H baut intal
0.75~2.2 0,75 kW~2,2 kW Gbr2 125 171 165 112 160 M4

Tilu fase runtuyan 380V

Motor aplikatif (kW) Modél No. Diagram Ukuran: (mm)
220 séri A B C G H baut intal
0.75~2.2 0,75kW~2,2kW Gbr2 125 171 165 112 160 M4
4 4kW 150 220 175 138 208 M5
5.5~7.5 5.5kW~7.5kW 217 300 215 205 288 M6
11 11 kW Gbr3 230 370 215 140 360 M8
15~22 15kW~22kW 255 440 240 200 420 M10
30~37 30kW~37kW 315 570 260 230 550
45~55 45kW~55kW 320 580 310 240 555
75~93 75kW~93kW 430 685 365 260 655
110~132 110kW~132kW 490 810 360 325 785
160~200 160kW~200kW 600 900 355 435 870
220 200kW~250kW Gbr4 710 1700 410 Pamasangan kabinét badarat
250
280 280kW~400kW 800 1900 420
315

2 3 4

Penampilan sarta ningkatna dimensi

Ukuran bentuk tingali Gbr2, Gbr3, Gbr4, bentuk kasus operasi tingali Gbr1

3 4

1.Frequency konversi énergi hemat

Énergi hemat converter frékuénsi utamana ditémbongkeun dina aplikasi tina kipas na pompa cai.Saatos régulasi laju frékuénsi variabel diadopsi pikeun beban kipas sareng pompa, tingkat hemat daya nyaéta 20% ~ 60%, sabab konsumsi kakuatan saleresna kipas sareng beban pompa dasarna sabanding sareng kakuatan katilu laju.Nalika aliran rata-rata anu dibutuhkeun ku pangguna leutik, kipas sareng pompa ngadopsi régulasi laju konversi frékuénsi pikeun ngirangan kagancanganna, sareng éfék hemat energi écés pisan.Nalika kipas sareng pompa tradisional nganggo baffle sareng klep pikeun pangaturan aliran, laju motor dasarna henteu robih, sareng pamakean kakuatan sakedik robih.Numutkeun statistik, konsumsi kakuatan kipas sareng motor pompa nyababkeun 31% tina konsumsi kakuatan nasional sareng 50% tina konsumsi kakuatan industri.Penting pisan ngagunakeun alat pangaturan laju konversi frékuénsi dina beban sapertos kitu.Ayeuna, aplikasi anu langkung suksés kalebet suplai cai tekanan konstan, pangaturan laju frékuénsi variabel tina sababaraha kipas, AC sentral sareng pompa hidrolik.

2.Frequency konversi énergi hemat

Énergi hemat converter frékuénsi utamana ditémbongkeun dina aplikasi tina kipas na pompa cai.Saatos régulasi laju frékuénsi variabel diadopsi pikeun beban kipas sareng pompa, tingkat hemat daya nyaéta 20% ~ 60%, sabab konsumsi kakuatan saleresna kipas sareng beban pompa dasarna sabanding sareng kakuatan katilu laju.Nalika aliran rata-rata anu dibutuhkeun ku pangguna leutik, kipas sareng pompa ngadopsi régulasi laju konversi frékuénsi pikeun ngirangan kagancanganna, sareng éfék hemat energi écés pisan.Nalika kipas sareng pompa tradisional nganggo baffle sareng klep pikeun pangaturan aliran, laju motor dasarna henteu robih, sareng pamakean kakuatan sakedik robih.Numutkeun statistik, konsumsi kakuatan kipas sareng motor pompa nyababkeun 31% tina konsumsi kakuatan nasional sareng 50% tina konsumsi kakuatan industri.Penting pisan ngagunakeun alat pangaturan laju konversi frékuénsi dina beban sapertos kitu.Ayeuna, aplikasi anu langkung suksés kalebet suplai cai tekanan konstan, pangaturan laju frékuénsi variabel tina sababaraha kipas, AC sentral sareng pompa hidrolik.

3.Application dina ngaronjatkeun tingkat prosés jeung kualitas produk

Konverter frékuénsi ogé tiasa seueur dianggo dina sababaraha widang kontrol alat mékanis sapertos pangiriman, angkat, ékstrusi sareng alat mesin.Éta tiasa ningkatkeun tingkat prosés sareng kualitas produk, ngirangan dampak sareng bising alat, sareng manjangkeun umur jasa alat.Saatos nganut kontrol régulasi laju konversi frékuénsi, sistem mékanis disederhanakeun, sareng operasi sareng kontrol langkung merenah.Sababaraha malah bisa ngarobah spésifikasi prosés aslina, sahingga ngaronjatkeun fungsi sakabéh parabot.Salaku conto, pikeun tékstil sareng mesin ukuran anu dianggo dina seueur industri, suhu di jero mesin disaluyukeun ku cara ngarobah jumlah hawa panas.Kipas sirkulasi biasana dianggo pikeun ngirimkeun hawa panas.Kusabab laju kipas angger, jumlah hawa panas anu disuap ngan ukur tiasa disaluyukeun ku damper.Lamun damper nu gagal pikeun nyaluyukeun atawa improperly disaluyukeun, mesin molding bakal leungit kontrol, sahingga mangaruhan kualitas produk rengse.Kipas sirkulasi dimimitian dina laju anu luhur, sareng ngagem antara sabuk drive sareng bantalan parah pisan, ngajantenkeun sabuk drive janten konsumsi.Saatos pangaturan laju konversi frékuénsi diadopsi, pangaturan suhu tiasa diwujudkeun ku konverter frékuénsi pikeun otomatis nyaluyukeun laju kipas, anu ngarengsekeun masalah kualitas produk.Sajaba ti éta, konverter frékuénsi bisa kalayan gampang ngamimitian kipas dina frékuénsi lemah sareng speed low, ngurangan maké antara sabuk drive na bearing nu, manjangkeun umur jasa pakakas, sarta ngahemat énergi ku 40%.

4.Realization motor mimiti lemes

Mimitian teuas motor teu ngan bakal ngabalukarkeun dampak serius dina grid kakuatan, tapi ogé merlukeun teuing kapasitas grid kakuatan.Arus ageung sareng geter anu dibangkitkeun nalika ngamimitian bakal nyababkeun karusakan anu ageung kana baffles sareng klep, sareng bakal ngabahayakeun pisan pikeun kahirupan jasa alat sareng pipa.Sanggeus ngagunakeun inverter nu, fungsi mimiti lemes tina inverter bakal nyieun robah ayeuna dimimitian ti enol, sarta nilai maksimum moal ngaleuwihan arus dipeunteun, ngurangan dampak dina grid kakuatan sarta sarat pikeun kapasitas catu daya, dilegaan jasa. hirup pakakas sarta valves, sarta ogé nyimpen biaya pangropéa pakakas

Spésifikasi

Jinis tegangan: 380V sareng 220V
Kapasitas Motor Applicative: 0.75kW mun 315kW
Spésifikasi tingali Table1

Voltaseu Modél No. Kapasitas dipeunteun (kVA) Arus kaluaran dipeunteun (A) Motor aplikatif (kW)
380V
tilu-fase
RDI67-0.75G-A3 1.5 2.3 0.75
RDI67-1.5G-A3 3.7 3.7 1.5
RDI67-2.2G-A3 4.7 5.0 2.2
RDI67-4G-A3 6.1 8.5 4.0
RDI67-5.5G / 7.5P-A3 11 13 5.5
RDI67-7.5G / 11P-A3 14 17 7.5
RDI67-11G / 15P-A3 21 25 11
RDI67-15G / 18.5P-A3 26 33 15
RDI67-18.5G / 22P-A3 31 39 18.5
RDI67-22G / 30P-A3 37 45 22
RDI67-30G / 37P-A3 50 60 30
RDI67-37G / 45P-A3 61 75 37
RDI67-45G / 55P-A3 73 90 45
RDI67-55G / 75P-A3 98 110 55
RDI67-75G / 90P-A3 130 150 75
RDI67-93G / 110P-A3 170 176 90
RDI67-110G / 132P-A3 138 210 110
RDI67-132G / 160P-A3 167 250 132
RDI67-160G / 185P-A3 230 310 160
RDI67-200G / 220P-A3 250 380 200
RDI67-220G-A3 258 415 220
RDI67-250G-A3 340 475 245
RDI67-280G-A3 450 510 280
RDI67-315G-A3 460 605 315
220V
fase tunggal
RDI67-0.75G-A3 1.4 4.0 0.75
RDI67-1.5G-A3 2.6 7.0 1.2
RDI67-2.2G-A3 3.8 10.0 2.2

runtuyan 220V fase tunggal

Motor aplikatif (kW) Modél No. Diagram Ukuran: (mm)
220 séri A B C G H baut intal
0.75~2.2 0,75 kW~2,2 kW Gbr2 125 171 165 112 160 M4

Tilu fase runtuyan 380V

Motor aplikatif (kW) Modél No. Diagram Ukuran: (mm)
220 séri A B C G H baut intal
0.75~2.2 0,75kW~2,2kW Gbr2 125 171 165 112 160 M4
4 4kW 150 220 175 138 208 M5
5.5~7.5 5.5kW~7.5kW 217 300 215 205 288 M6
11 11 kW Gbr3 230 370 215 140 360 M8
15~22 15kW~22kW 255 440 240 200 420 M10
30~37 30kW~37kW 315 570 260 230 550
45~55 45kW~55kW 320 580 310 240 555
75~93 75kW~93kW 430 685 365 260 655
110~132 110kW~132kW 490 810 360 325 785
160~200 160kW~200kW 600 900 355 435 870
220 200kW~250kW Gbr4 710 1700 410 Pamasangan kabinét badarat
250
280 280kW~400kW 800 1900 420
315

2 3 4

Penampilan sarta ningkatna dimensi

Ukuran bentuk tingali Gbr2, Gbr3, Gbr4, bentuk kasus operasi tingali Gbr1

3 4

Kategori produk

Tulis pesen anjeun di dieu sareng kirimkeun ka kami